AXUM - The Facts | Smart in Soluons
19
AXUM engine card
The AXUM engine card controls the enre rack system.
All informaon for the rack is processed on this card.
The RJ45 Connector should be connected
to the Ethernet switch that is connected to
all MambaNet™ compable devices.
Advanced funcons can be accessed by using
the following interface connectors:
RS232
VGA
Keyboard
Mouse
USB
On the BNC connecon you can connect a word clock
output signal or a word clock input signal. The input signal
can be terminated with 75 Ohm using the latching switch.
DSP card
By plugging a DSP card in the I/O rack you add mixing
capabilies to your matrix. In combinaon with the
engine card you will get an advanced mixing console.
The DSP card processes 32 stereo channels to 16
stereo busses and 4 stereo monitoring busses.
On an input channel the following processing is available:
Low cut
Gain
EQ
Dynamics
Level meter
pre/post switching
You can insert a maximum of 4 DSP boards.
This gives you a mixing console of 128 stereo channels to
16 stereo busses as well as 16 stereo monitoring busses.